QS water wet submersible pump product instruction
QS type water filling type submersible electric pump is composed of two parts, motors, pumps, water pumps in the pump is centrifugal structure, pump motor is located in the lower part, water filling type three-phase asynchronous motor. Water filled motor stator windingand iron core is directly immersed in water, good cooling effect, high output power, high efficiency. Three-phase motor consists of rolling bearing and the two sliding bearing, sliding bearings are made of high quality stainless steel graphite sleeve and thrust plate,respectively, under the electric pump when the radial force and axial force, stable performance, reliable quality, sealing ring and sand capmotor.
QS water wet submersible pump product feature
1, QS water wet submersible electric pump is composed of motor,pump are assembled into a whole, has the advantages of simple structure, convenient installation and disassembly, and installation covers an area of small, simple operation, safe and reliable operation.
2, QS water wet submersible pump cooling effect is good, no pollution, improve the use efficiency of the water pump.
3, QS water wet submersible pump because of its special structure,the use of water does not produce pollution.
QS water wet submersible pump use condition
QS pump should be able to work normally and continuously under the following conditions:
1, the temperature of the medium is not more than +40 ℃;
2, medium pH in 6.58.5 between;
3, containing solid impurity volume ratio of not more than 0.1%,particle size less than 0.2mm;
4, the power frequency is 50Hz, voltage is 380V, voltage fluctuationrange of 0.91.1 times the rated value;
5, the diving depth of not less than 0.5m.
QS water wet submersible pump model sense
For example: QS20-40/2-4
QS- water filling type submersible pump
The flow rate of 20- (m3/h)
40- lift (m)
2- series
4- power (kw)
QS water wet submersible pump technology parameter
Traffic: 15-2200m3/h;
Head: 5.5-60m;
Speed: 2860r/min;
Aperture: φ 50- φ 10
Working pressure: ≤ 1.0Mpa;
Medium temperature ≤ 40 ℃.